Alon Refining (3116), Krotz Springs

Releases in 2007

LDEQ Accident Number
Accident Date
Point Source/Release CauseNotes
100898

2007-11-08
Point Source(s):
Main Crude Charge Pump

Pollutant(s):
Crude Oil - 3 gallons
Cause of Problem: Other- Fire

xxxxxxxx
There was a fire at the Main Crude Charge Pump, no cause for the fire was given.
No LDEQ Number Available

2007-10-15
Point Source(s):
Shut down of FCCU Unit

Pollutant(s):
No Information Given - BRQ
Cause of Problem: Start Up, Shut Down

xxxxxxxx
Need to find LDEQ #. Report said that the unit was back online 10/18/05-which is probably a typo.
No LDEQ Number Available

2007-10-14
Point Source(s):
Fin Fan Leak in Poly Unit

Pollutant(s):
Butane - 979 pounds
Cause of Problem: Equipment Failure

xxxxxxxx
Need to find LDEQ #. A small leak was discovered in the Fin Fan in the Poly Unit so the unit was shut down immediately. It re-opened 10/18/2007. All the tubes were re-rolled and then hydrotested for additional leaks and none were found.
99248

2007-09-07
Point Source(s):
Fin Fan Leak in Poly Unit

Pollutant(s):
Butane - 730 pounds
Cause of Problem: Equipment Failure

xxxxxxxx
A small leak was discovered in the a tube of a Fin Fan in the Poly Unit so the unit was shut down immediately. It re-opened 09/08/2007. The tubes were hydrotested for additional leaks and none were found.
99045

2007-08-16
Point Source(s):
Leak in tube of Poly Debutanizer Overhead Fin Fans in Poly Unit

Pollutant(s):
Butane - 337 pounds
Cause of Problem: Equipment Failure

xxxxxxxx
A pin-hole sized leak was discovered in the a tube of a Poly Debutanizer Overhead Fin Fan in the Poly Unit so the unit was shut down immediately It re-opened 08/11/2007. It was shut down again on 8/14/2007 to replace the bundle of tubes.
98022

2007-07-20
Point Source(s):
Fin Fan Leak in Poly Unit

Pollutant(s):
Butane - 211 pounds
Cause of Problem: Equipment Failure

xxxxxxxx
A pin-hole sized leak was discovered in the Fin Fan in the Poly Unit so the unit was shut down shortly after. It re-opened 07/21/2007.
97619

2007-07-05
Point Source(s):
Fin Fan Leak in Poly Unit

Pollutant(s):
Butane - 192 pounds
Cause of Problem: Equipment Failure

xxxxxxxx
A pin-hole sized leak was discovered in the Fin Fan in the Poly Unit so the unit was shut down. It re-opened 07-07/2007.
96724

2007-06-04
Point Source(s):
equipment malfunction in FCCU (Complex II)

Pollutant(s):
No Information Given - BRQ
Cause of Problem: Start Up, Shut Down

Start Up, Shut Down - Due to equipment malfunction
The unplanned shutdown was caused by an equipment malfunction and daily updates were made until unit was secured.
96558

2007-05-27
Point Source(s):
Hatch on Barge CTCO 351-B (D1149816)

Pollutant(s):
Diesel Fuel - 210 gallons
Cause of Problem: Human Factors

Operator over-filled barge and it spilled into river
Actual Incident Report still needs to be found. There were two NRC reports. The first said 2 bbl were released. The second said 50 were released and 40 bbl were in the water. The police report said 50 bbl were released, then changed that to 5 bbl and then to an estimated 8-12 bbl. Absorbent boom was placed to contain the spill.
94106

2007-02-21
Point Source(s):
Resid pump in Crude Unit (Complex I)

Pollutant(s):
Resid - BRQ
Cause of Problem: No information given

xxxxxxxx
Resid pump blew a seal.